{"id":865,"date":"2017-08-28T11:37:07","date_gmt":"2017-08-28T18:37:07","guid":{"rendered":"http:\/\/atsduct.com\/?page_id=865"},"modified":"2018-03-26T00:29:17","modified_gmt":"2018-03-26T07:29:17","slug":"static-safe","status":"publish","type":"page","link":"https:\/\/previous.atsduct.com\/zh\/reference\/static-safe\/","title":{"rendered":"Static Safe"},"content":{"rendered":"<p>ATS Inc. is proud to offer the only FM approved duct available with a StaticSafe&#x2122; conductive liner.<\/p>\n<p>ATS StaticSafe Duct&#x2122; maintains all the features of ATS FXP&#x2122; which has made ATS Inc. a leader in the field of Exhaust Duct Systems:<\/p>\n<ul>\n<li>Corrosion Resistance<\/li>\n<li>Fire Resistance<\/li>\n<li>Strength<\/li>\n<li>No Leakage at Joints<\/li>\n<li>Extremely low emission of VOCs during installation<\/li>\n<li>Ease of Installation<\/li>\n<li>Ease of Modification on a live system<\/li>\n<li>Low weight to strength ratio<\/li>\n<\/ul>\n<p>In addition to the benefits of ATS FXP&#x2122;, ATS StaticSafe Duct&#x2122; offers additional protection against static discharge when exhausting flammable or explosive gases.<\/p>\n<div class=\"row\">\n<div class=\"col-lg-8 col-lg-offset-2\">\n<table class=\"table table-responsive\">\n<thead>\n<tr>\n<th colspan=\"3\">Chemical Applications &#8211; Flammables<\/th>\n<\/tr>\n<tr>\n<th>Flammable Gases<\/th>\n<th>Flammable Liquids\/Vapors<\/th>\n<th>Pyrophoric Gases<br \/>\n(explosive when mixed with air and must be<br \/>\nblanketed with nitrogen or argon)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Ammonica<\/td>\n<td>Isopropyl Alcohol<\/td>\n<td>Diborane<\/td>\n<\/tr>\n<tr>\n<td>Arsine<\/td>\n<td>Methanol<\/td>\n<td>Silane<\/td>\n<\/tr>\n<tr>\n<td>Dichlorsilane<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Hydrogen<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Phosphine<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p>For part types and dimensions for StaticSafe Duct&#x2122;, refer to the Mechanical Drawing Guide (Pg. 54) for ATS FXP&#x2122;.<\/p>\n<h3>Composition of StaticSafe Duct&#x2122;<\/h3>\n<p>Internal Corrosion Resistant Conductive Liner<\/p>\n<p>StaticSafe\u00e2\u0080\u0099s&#x2122; high corrosion resistance compliments its conductivity to make a product that is desirable for corrosive exhaust applications where there is the potential for venting explosive gases and static dissipation is required.<\/p>\n<h3>External Fire Resistant Shell<\/h3>\n<p>ATS uses a low smoke, fire safe resin to provide a rigid structural shell, which encloses the corrosion resistant conductive liner.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"center-block img-responsive aligncenter wp-image-877 size-large\" src=\"http:\/\/atsduct.com\/wp-content\/uploads\/2017\/08\/ATS-Reference-Guide-2017b-FXP-v5-206-1024x440.jpg\" alt=\"\" width=\"1024\" height=\"440\" srcset=\"https:\/\/previous.atsduct.com\/wp-content\/uploads\/2017\/08\/ATS-Reference-Guide-2017b-FXP-v5-206-1024x440.jpg 1024w, https:\/\/previous.atsduct.com\/wp-content\/uploads\/2017\/08\/ATS-Reference-Guide-2017b-FXP-v5-206-300x129.jpg 300w, https:\/\/previous.atsduct.com\/wp-content\/uploads\/2017\/08\/ATS-Reference-Guide-2017b-FXP-v5-206-768x330.jpg 768w, https:\/\/previous.atsduct.com\/wp-content\/uploads\/2017\/08\/ATS-Reference-Guide-2017b-FXP-v5-206.jpg 1140w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<p>ATS Conductive H-Collar&#x2122; and ATS Conductive Slip Collar&#x2122; with ATS Conductive Putty&#x2122; are used for joining duct sections. There is no need for using cumbersome grounding straps or wires across joints! The joints themselves are conductive. The StaticSafe Duct&#x2122; system is self-grounding.<\/p>\n<div class=\"row\">\n<div class=\"col-sm-3\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-881 img-responsive\" src=\"http:\/\/atsduct.com\/wp-content\/uploads\/2017\/08\/FM-Approved-279x300.jpg\" alt=\"\" width=\"279\" height=\"300\" srcset=\"https:\/\/previous.atsduct.com\/wp-content\/uploads\/2017\/08\/FM-Approved-279x300.jpg 279w, https:\/\/previous.atsduct.com\/wp-content\/uploads\/2017\/08\/FM-Approved.jpg 350w\" sizes=\"auto, (max-width: 279px) 100vw, 279px\" \/><\/div>\n<div class=\"col-sm-9\">\n<p>ATS StaticSafe Duct&#x2122; is Factory Mutual FM4922-Approved.Factory Mutual Approvals approves ATS StaticSafe Duct&#x2122; to be used for fume and smoke removal in cleanrooms without the need for interrupters or automatic sprinkler protection.<\/p>\n<p>ATS StaticSafe Duct&#x2122; is also FM 4910 Approved. It meets FM\u00e2\u0080\u0099s requirements for smoke damage (SDI) and fire propagation (FPI).<\/p>\n<p>Delsen Test Report \u00e2\u0080\u0093 StaticSafe&#x2122; has been tested for volume and surface resistivity with a measurement of 0.60 Ohms-cm and 4.7 Ohms per square*, respectively, which exceeds common requirements for conductivity of 1 million Ohms-cm (1&#215;106). Request Delsen test report dated 5\/11\/01.<\/p>\n<\/div>\n<\/div>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"center-block img-responsive aligncenter wp-image-889\" src=\"http:\/\/atsduct.com\/wp-content\/uploads\/2017\/08\/SS_Comp_Chart-1024x701.jpg\" alt=\"\" width=\"731\" height=\"500\" srcset=\"https:\/\/previous.atsduct.com\/wp-content\/uploads\/2017\/08\/SS_Comp_Chart-1024x701.jpg 1024w, https:\/\/previous.atsduct.com\/wp-content\/uploads\/2017\/08\/SS_Comp_Chart-300x205.jpg 300w, https:\/\/previous.atsduct.com\/wp-content\/uploads\/2017\/08\/SS_Comp_Chart-768x525.jpg 768w, https:\/\/previous.atsduct.com\/wp-content\/uploads\/2017\/08\/SS_Comp_Chart.jpg 1140w\" sizes=\"auto, (max-width: 731px) 100vw, 731px\" \/><\/p>\n<p><strong>1<\/strong> See Delsen Test Report 05\/11\/01, pg. 3.<\/p>\n<p><strong>2<\/strong> See Delsen Test Report 05\/11\/01, pg. 12. (This uses the following formula: Surface Resistivity= (Width\/Potential Electrode Distance) X Resistance (0.33in \/0.44in) x 1.21 = .998 Ohms<\/p>\n<p><strong>3<\/strong> See Delsen Test Report 05\/31\/00, pg. 3.<\/p>\n<p>Delsen Test Report \u00e2\u0080\u0093 ATS StaticSafe&#x2122; has been tested for volume and surface resistivity with a measurement of 0.60 Ohms-cm and 4.7 Ohms per square**, respectively, which exceeds common requirements for conductivity of 1 million Ohms-cm (1&#215;10<sup>6<\/sup>).<\/p>\n<p>* Surface resistivity is expressed in ohms per square, without reference to the size of the square.<\/p>\n<p>The ESD Association Glossary, ESD-ADV 1.0-1994 (1), describes Surface Resistivity in the following way: \u00e2\u0080\u009cFor an electric current flowing across a surface, the ratio of DC voltage drop per unit length to the surface current per width. In effect, the surface resistivity is the resistance between two opposite sides of a square and is independent of the size of the square or its dimensional units.<\/p>\n<p>** Resistance (ohms) is the property of a substance to resist the flow of electrical current.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>ATS Inc. is proud to offer the only FM approved duct available with a StaticSafe&#x2122; conductive liner. ATS StaticSafe Duct&#x2122; maintains all the features of ATS FXP&#x2122; which has made ATS Inc. a leader in the field of Exhaust Duct Systems: Corrosion Resistance Fire Resistance Strength No Leakage at Joints Extremely low emission of VOCs [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":832,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-865","page","type-page","status-publish","hentry"],"translation":{"provider":"WPGlobus","version":"3.0.2","language":"zh","enabled_languages":["en","ko","zh"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"ko":{"title":true,"content":true,"excerpt":false},"zh":{"title":false,"content":false,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/previous.atsduct.com\/zh\/wp-json\/wp\/v2\/pages\/865","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/previous.atsduct.com\/zh\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/previous.atsduct.com\/zh\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/previous.atsduct.com\/zh\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/previous.atsduct.com\/zh\/wp-json\/wp\/v2\/comments?post=865"}],"version-history":[{"count":25,"href":"https:\/\/previous.atsduct.com\/zh\/wp-json\/wp\/v2\/pages\/865\/revisions"}],"predecessor-version":[{"id":2017,"href":"https:\/\/previous.atsduct.com\/zh\/wp-json\/wp\/v2\/pages\/865\/revisions\/2017"}],"up":[{"embeddable":true,"href":"https:\/\/previous.atsduct.com\/zh\/wp-json\/wp\/v2\/pages\/832"}],"wp:attachment":[{"href":"https:\/\/previous.atsduct.com\/zh\/wp-json\/wp\/v2\/media?parent=865"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}